Schneider Electric - 5 Amp, 240 VAC, 2 Pole, DIN Rail Mounted Miniature Circuit Breaker - Thermal Magnetic Trip, 20 kA at 240 VAC Breaking Capacity, 14-4 AWG, 76mm Deep x 81mm High x 36mm Wide


Item #: 54529383
Brand: Schneider Electric
Model #: 60240
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 5
Number of Poles 2
Breaking Capacity 20 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type DIN Rail Mounted
Voltage 240 VAC
Wire Size (sq mm) 2-25
Wire Size (AWG) 14-4
Durability 4000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (Decimal Inch) 3
Overall Depth (mm) 76
Overall Height (mm) 81
Overall Height (Decimal Inch) 3.1900
Overall Width (mm) 36
Overall Width (Decimal Inch) 1.4200
Standards Met CE Marked; CSA C22.2 No. 5.1 Circuit Breakers: File No. 179014; IEC 60947-2; UL 489 Circuit Breakers: File No. E215117
Reset Actuator Type Handle

$333.36

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 30 Amp, 480Y/277 VAC, 3 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41399502
Brand: Square D
Model #: BDA34030Y
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 30
Number of Poles 3
Breaking Capacity 25 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 480Y/277 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type Toggle Switch

$982.82

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Amp, 440 VAC, 1 Pole, DIN Rail Mounted Miniature Circuit Breaker - Magnetic Trip, Multiple Breaking Capacity Ratings, 18-4 AWG, 76mm Deep x 81mm High x 18mm Wide


Item #: 56786858
Brand: Schneider Electric
Model #: M9F15103
Exact Tooling IR#: 04

Features and Benefits

Magnetic tripping mechanisms are designed with a solenoid (electromagnet), which will quickly disconnect in case of a short circuit or overload. They are not greatly affected by extreme environmental conditions, but are sensitive to low-overloads.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 3
Number of Poles 1
Breaking Capacity 15 kA @ 230/240 VAC; 30 kA @ 130 VAC; 4 kA @ 400/415 VAC
Tripping Mechanism Magnetic
Terminal Connection Type Box Lugs
Mounting Type DIN Rail Mounted
Voltage 440 VAC
Wire Size (sq mm) 1-25
Wire Size (AWG) 18-4
Durability 10000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (Decimal Inch) 3
Overall Depth (mm) 76
Overall Height (mm) 81
Overall Height (Decimal Inch) 3.1900
Overall Width (mm) 18
Overall Width (Decimal Inch) 0.7100
For Use With Multi 9 Modular System
Standards Met IEC Certified; UL Listed; UL Recognized
Reset Actuator Type Toggle Switch

$147.78

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 400 Amp, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 25 kA at 600 VAC Breaking Capacity, 3/0 AWG, 8.05 Inch Deep x 12.86 Inch High x 8.27 Inch Wide


Item #: 56765738
Brand: Square D
Model #: LDL36400CU31XMA
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 400
Number of Poles 3
Breaking Capacity 25 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 600 VAC
Wire Size (AWG) 3/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 8.0500
Overall Height (Decimal Inch) 12.8600
Overall Width (Decimal Inch) 8.2700
Standards Met IEC 60947-2; OSHA Requirements; UL 489
Reset Actuator Type Toggle Switch

$10,368.41

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 30 Amp, 250 VDC, 600 VAC, 2 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG


Item #: 56746795
Brand: Square D
Model #: HGL26030
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 30
Number of Poles 2
Breaking Capacity 18 kA @ 600 VAC; 20 kA @ 250 VDC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0

$1,360.51

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 50 Amp, 347 VAC, 1 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 100 kA at 240 VAC, 25 kA at 347 VAC, 65 kA at 277 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41397431
Brand: Square D
Model #: BJA160501
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 50
Number of Poles 1
Breaking Capacity 100 kA @ 240 VAC; 25 kA @ 347 VAC; 65 kA @ 277 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 347 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Reset Actuator Type Toggle Switch

$736.95

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Brand: Widia / Part #: 3992549


Item #: 86416559
Brand: Widia
Model #: 3992549

Product Specifications

Minimum Drill Diameter (Decimal Inch) 0.5315
Maximum Drill Diameter (Decimal Inch) 0.5508
Drill Depth by Diameter Ratio 8xD
Maximum Drill Depth (Decimal Inch) 4.4094
Shank Type Cylindrical
Insert Style TDM
Shank Diameter (Inch) 9/16
Shank Diameter (Decimal Inch) 0.5625
Insert Seat Size W21
Tool Material Steel
Compatible Insert Style TDM
Compatible Insert Size Code W21
Overall Length (Decimal Inch) 7.2520
Series TDM1
Toolholder Style TDM1
Flute Length (Decimal Inch) 5.3425
Body Length (Decimal Inch) 6.9745
Shank Length (Decimal Inch) 1.7902
Tool Application Drilling
Tool Performance General Purpose
Primary Workpiece Material Universal
Tip Length (Decimal Inch) 0.0984
Cutting Direction Right Hand
Coolant Through Yes
Number Of Flutes 2

$295.23

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 30 Amp, 120/240 VAC, 2 Pole, DIN Rail Mounted, Flush Mount, Surface Mount Miniature Circuit Breaker - Thermal Magnetic Trip, 10 kA at 120/240 VAC Breaking Capacity, 14-2 (Aluminum), 14-2 (Copper) AWG, 74mm Deep x 103mm High x 19mm Wide


Item #: 54523352
Brand: Square D
Model #: QOUQ230B
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 30
Number of Poles 2
Breaking Capacity 10 kA @ 120/240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Pressure Plate
Mounting Type DIN Rail Mounted; Flush Mount; Surface Mount
Voltage 120/240 VAC
Wire Size (AWG) 14-2 (Aluminum); 14-2 (Copper)
Overall Depth (Decimal Inch) 2.9200
Overall Depth (mm) 74
Overall Height (mm) 103
Overall Height (Decimal Inch) 4.0500
Overall Width (mm) 19
Overall Width (Decimal Inch) 3/4
For Use With I-Line Panelboards & Switchboards
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; UL Listed
Reset Actuator Type Toggle Switch

$108.18

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 50 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, 88.6mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56740400
Brand: Square D
Model #: HGL36050M38X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 50
Number of Poles 3
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Maximum Operating Temperature (F) 104
Overall Depth (Decimal Inch) 3.4900
Overall Depth (mm) 88.60
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
For Use With Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met CSA Certified; IEC 647-2 Icu/Ics; NOM; UL Listed
Reset Actuator Type Toggle Switch

$2,290.96

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 70 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 25 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56748387
Brand: Square D
Model #: HJL36070AA
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 70
Number of Poles 3
Breaking Capacity 25 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 4.3600
Overall Depth (mm) 110.80
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$2,832.36

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Brand: E-Z UP / Part #: SWP3FXTM15BK


Item #: 67538892
Brand: E-Z UP
Model #: SWP3FXTM15BK

Product Specifications

Product Type Sidewall
Material Polyester
For Use With Eclipse
Includes (1) 15' TAA Compliant Mid-Zip Sidewall (Black)
Color Black

$310.86

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 225 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG


Item #: 54522198
Brand: Square D
Model #: JDL36225
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 225
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC; 18 kA @ 480 VAC; 20 kA @ 250 VDC; 25 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0
Standards Met RoHS Compliant

$2,964.21

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 200 Amp, 690 VAC, 4 Pole, Fixed Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 86mm Deep x 161mm High x 140mm Wide


Item #: 56741317
Brand: Square D
Model #: LV431651
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 4
Breaking Capacity 15 kA @ 600 VAC; 20 kA @ 600 VAC; 22 kA @ 525 VAC; 30 kA @ 500 VAC; 35 kA @ 440 VAC; 35 kA @ 480 VAC; 36 kA @ 380/415 VAC; 8 kA @ 660/690 VAC; 85 kA @ 220/240 VAC; 85 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Mounting Type Fixed
Voltage 690 VAC
Durability 5000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -31
Overall Depth (mm) 86
Overall Height (mm) 161
Overall Width (mm) 140
Standards Met CSA Certified; EN 60947-2; IEC 60947-2; NEMA AB1; UL 508; UL Listed
Reset Actuator Type Toggle Switch

$4,174.10

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 25 Amp, 277 Volt, 1 Pole, Clip Mount C60BP - Branch Protection Circuit Breaker - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG


Item #: 46120903
Brand: Schneider Electric
Model #: M9F42125
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type C60BP - Branch Protection
Amperage 25
Number of Poles 1
Breaking Capacity 3 kA @ 415 VAC; 10 kA @ 240 VAC; 20 kA @ 60 VDC; 10 kA @ 277 VAC; 14 kA @ 240 VAC; 14 kA @ 120 VAC; 10 kA @ 60 VDC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type Clip
Voltage 277 V
Wire Size (AWG) 18-8
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Height (Decimal Inch) 4.0600
Overall Length (Decimal Inch) 2.8300
Overall Width (Decimal Inch) 0.7100
For Use With OEM Panel
Standards Met UL 489; IEC; CSA; CCC
Reset Actuator Type Toggle Switch

$115.70

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 30 Amp, 240 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 12-4 (Aluminum), 14-4 (Copper) AWG, 4.13 Inch Deep x 6 Inch High x 4-1/2 Inch Long


Item #: 69668085
Brand: Square D
Model #: FAL32030
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 30
Number of Poles 3
Breaking Capacity 1 kA @ 240 VAC; 18/25 kA @ 480 VAC; 25 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 240 VAC
Wire Size (AWG) 12-4 (Aluminum); 14-4 (Copper)
Minimum Operating Temperature (F) 104
Overall Depth (Decimal Inch) 4.1300
Overall Height (Inch) 6
Overall Length (Decimal Inch) 4-1/2
For Use With Industrial Enclosures & Switchboards
Standards Met CSA Certified; Federal Specification W-C 375 b/Gen; IEC Rated; UL Listed
Reset Actuator Type Toggle Switch

$753.30

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 4 Amp, 440 VAC, 2 Pole, DIN Rail Mounted Miniature Circuit Breaker - Magnetic Trip, Multiple Breaking Capacity Ratings, 18-4 AWG, 76mm Deep x 81mm High x 36mm Wide


Item #: 56787286
Brand: Schneider Electric
Model #: M9F11204
Exact Tooling IR#: 04

Features and Benefits

Magnetic tripping mechanisms are designed with a solenoid (electromagnet), which will quickly disconnect in case of a short circuit or overload. They are not greatly affected by extreme environmental conditions, but are sensitive to low-overloads.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 4
Number of Poles 2
Breaking Capacity 10 kA @ 400-415 VAC; 20 kA @ 230-240 VAC; 6 kA @ 440 VAC
Tripping Mechanism Magnetic
Terminal Connection Type Box Lugs
Mounting Type DIN Rail Mounted
Voltage 440 VAC
Wire Size (sq mm) 1-25
Wire Size (AWG) 18-4
Durability 10000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (Decimal Inch) 3
Overall Depth (mm) 76
Overall Height (mm) 81
Overall Height (Decimal Inch) 3.1900
Overall Width (mm) 36
Overall Width (Decimal Inch) 1.4200
For Use With Multi 9 Modular System
Standards Met IEC Certified; UL Listed; UL Recognized
Reset Actuator Type Toggle Switch

$244.71

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 50 Amp, 240 VAC, 2 Pole, Panel Mount Miniature Circuit Breaker - 14-2 AWG


Item #: 56788797
Brand: Square D
Model #: QOU2501021
Exact Tooling IR#: 04

Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 50
Number of Poles 2
Terminal Connection Type Box Lugs
Mounting Type Panel Mount
Voltage 240 VAC
Wire Size (AWG) 14-2
For Use With Shunt Trip 120/208/240 VAC
Standards Met CSA; IEC; RoHS Compliant; UL Listed

$399.19

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 150 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 4-4/0 AWG


Item #: 56744451
Brand: Square D
Model #: JDL36150C
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC; 18 kA @ 480 VAC; 20 kA @ 250 VDC; 25 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 4-4/0
Standards Met RoHS Compliant

$3,872.65

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 35 Amp, 250 VDC, 600 VAC, 2 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 69.7mm Wide


Item #: 56739816
Brand: Square D
Model #: HDL26035SA
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 35
Number of Poles 2
Breaking Capacity 14 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 4.3600
Overall Depth (mm) 110.80
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 69.70
Overall Width (Decimal Inch) 2.7400
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$1,876.04

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 250 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 88.6mm Deep x 191mm High x 104.7mm Wide


Item #: 56742281
Brand: Square D
Model #: JGM36250U31X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 250
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Maximum Operating Temperature (F) 104
Overall Depth (Decimal Inch) 3.4900
Overall Depth (mm) 88.60
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
For Use With Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met CSA Certified; IEC 647-2 Icu/Ics; NOM; UL Listed
Reset Actuator Type Toggle Switch

$3,890.19

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It