Lighting & Electrical Products - Power Distribution & Generation Equipment For Sale | Caliber Tooling - (9098 Products)
Square D - 15 Amp, 240 VAC, 2 Pole, Panel Mount Miniature Circuit Breaker
Item #: 69529295
Brand: Square D
Model #: QOU2155283
Exact Tooling IR#: 04Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
15
Number of Poles
2
Terminal Connection Type
Ring Tongue
Mounting Type
Panel Mount
Voltage
240 VAC
Standards Met
CSA; IEC; RoHS Compliant; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 40 Amp, 120/240 VAC, 24 VDC, 48 VDC, 80 VDC, 2 Pole, Plug In Miniature Circuit Breaker - Thermal Magnetic Trip, 14-4 AWG, 2-3/8 Inch Deep x 2-15/16 Inch High x 2 Inch Wide
Item #: 04882312
Brand: Eaton Cutler-Hammer
Model #: HQP2040
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
40
Number of Poles
2
Tripping Mechanism
Thermal-Magnetic
Mounting Type
Plug-in
Voltage
120/240 VAC; 24 VDC; 48 VDC; 80 VDC
Wire Size (AWG)
14-4
Overall Depth (Inch)
2-3/8
Overall Height (Inch)
2-15/16
Overall Width (Inch)
2
Standards Met
CSA Listed; Federal Specification W-C-375b; UL Listed 489
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Brand: DoALL / Part #: 301-069262.000
Item #: 62439260
Brand: DoALL
Model #: 301-069262.000Product Specifications
Blade Length (Feet)
21' 10"
Blade Material
Bi-Metal
Teeth Per Inch
2-3
Blade Width (Inch)
2
Blade Thickness (Decimal Inch)
0.0630
Cutting Edge Style
Toothed
Tooth Set
Raker
Tooth Material
M 42 HSS
Tooth Form
Vari/Raker
Pitch Pattern
Variable
Contour Cutting
No
Material Application
Stainless Steel
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 225 Amp, 250 VDC, 600 VAC, 2 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG
Item #: 54522073
Brand: Square D
Model #: JJL26225
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
225
Number of Poles
2
Breaking Capacity
100 kA @ 240 VAC; 20 kA @ 250 VDC; 25 kA @ 600 VAC; 65 kA @ 480 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
250 VDC; 600 VAC
Wire Size (AWG)
3/0
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 400 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 2 AWG
Item #: 56764954
Brand: Square D
Model #: LLL36400U33X
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
400
Number of Poles
3
Breaking Capacity
100 kA @ 480 VAC; 125 kA @ 240 VAC; 50 kA @ 600 VAC
Tripping Mechanism
Electronic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
600 VAC
Wire Size (AWG)
2
Standards Met
CCC; CSA; IEC; RoHS Compliant; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 100 Amp, 240 VAC, 2 Pole, Panel Mount Miniature Circuit Breaker - 12-2/0 AWG
Item #: 69668895
Brand: Square D
Model #: QOU2100
Exact Tooling IR#: 04
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
100
Number of Poles
2
Terminal Connection Type
Box Lugs
Mounting Type
Panel Mount
Voltage
240 VAC
Wire Size (AWG)
12-2/0
Standards Met
CSA; IEC; RoHS Compliant; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 25 Amp, 480Y/277 VAC, 2 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 480Y/277 VAC Breaking Capacity, 14-2/0 AWG
Item #: 41398942
Brand: Square D
Model #: BDA24025Y1
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
25
Number of Poles
2
Breaking Capacity
25 kA @ 240 VAC; 18 kA @ 480Y/277VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
I-Line; Lug
Mounting Type
Panel Mount
Voltage
480Y/277 VAC
Wire Size (AWG)
14-2/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 0.40 Amp, 690 VAC at 50/60 Hz, 3 Pole, Bolt On, Clip Motor Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 78mm Deep x 89mm High x 45mm Wide
Item #: 76306679
Brand: Schneider Electric
Model #: GV2ME03
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Motor Circuit Breaker
Amperage
0.40
Number of Poles
3
Breaking Capacity
100 kA @ 230/240 VAC; 100 kA @ 400/415 VAC; 100 kA @ 440 VAC; 100 kA @ 500 VAC; 100 kA @ 690 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Screw
Mounting Type
Bolt-on; Clip
Voltage
690 VAC @ 50/60 Hz
Durability
100000 Cycles
Maximum Operating Temperature (F)
140
Minimum Operating Temperature (F)
-4
Overall Depth (mm)
78
Overall Height (mm)
89
Overall Width (mm)
45
For Use With
TeSys GV2
Standards Met
ATEX; Bureau Veritas; CCC; CEBEC; CSA; DNV; EZU; GL; GOST; IEC 60947-2; LROS; RINA; SETI; TSE; UL
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 400 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 2 AWG
Item #: 49787161
Brand: Square D
Model #: LJL36400U31X
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
400
Number of Poles
3
Breaking Capacity
100 kA @ 240 VAC; 25 kA @ 600 VAC; 65 kA @ 480 VAC
Tripping Mechanism
Electronic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
600 VAC
Wire Size (AWG)
2
Standards Met
CCC; CSA; IEC; RoHS Compliant; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 16 Amp, 480Y/277 Volt, 4 Pole, Clip Mount C60SP Circuit Breaker - Supplementary Protection - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG
Item #: 46120242
Brand: Schneider Electric
Model #: M9F23416
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
C60SP - Supplementary Protection
Amperage
16
Number of Poles
4
Breaking Capacity
14 kA @ 240 VAC; 10 kA @ 480Y/277 VAC; 6 kA @ 440 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
Clip
Voltage
480Y/277 V
Wire Size (AWG)
18-8
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Height (Decimal Inch)
3.1900
Overall Length (Decimal Inch)
2.8300
Overall Width (Decimal Inch)
2.8400
For Use With
OEM Panel
Standards Met
UL 1077; IEC; CSA; CCC
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 250 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 2 AWG
Item #: 56766330
Brand: Square D
Model #: LJL36250CU33X
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
250
Number of Poles
3
Breaking Capacity
100 kA @ 240 VAC; 25 kA @ 600 VAC; 65 kA @ 480 VAC
Tripping Mechanism
Electronic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
600 VAC
Wire Size (AWG)
2
Standards Met
CCC; CSA; IEC; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 350 Amp, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Electronic Trip, 18 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum), 3/0 (Copper) AWG, 8.05 Inch Deep x 12.86 Inch High x 8.27 Inch Wide
Item #: 56761034
Brand: Square D
Model #: MGL36350LW
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
350
Number of Poles
3
Breaking Capacity
18 kA @ 600 VAC
Tripping Mechanism
Electronic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
600 VAC
Wire Size (AWG)
3/0 (Aluminum); 3/0 (Copper)
Overall Depth (Decimal Inch)
8.0500
Overall Height (Decimal Inch)
12.8600
Overall Width (Decimal Inch)
8.2700
Standards Met
CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 40 Amp, 500 VDC, 2 Pole, Clip Mount C60H-DC Circuit Breaker - Supplementary Protection for Direct Current - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-2, 18-4, 18-6 AWG
Item #: 46117610
Brand: Schneider Electric
Model #: M9U21240
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
C60H-DC - Supplementary Protection for Direct Current
Amperage
40
Number of Poles
2
Breaking Capacity
20 kA @ 220 VDC; 10 kA @ 440 VDC; 6 kA @ 500 VDC; 5 kA @ 12-500 VDC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
Clip
Voltage
500 VDC
Wire Size (AWG)
18-2; 18-4; 18-6
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Height (Decimal Inch)
3.1900
Overall Length (Decimal Inch)
2.8300
Overall Width (Decimal Inch)
1.4200
For Use With
OEM Panel
Standards Met
UL 1077; IEC; CCC
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 10 Amp, 277 Volt, 1 Pole, Clip Mount C60SP Circuit Breaker - Supplementary Protection - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG
Item #: 46109799
Brand: Schneider Electric
Model #: M9F23110
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
C60SP - Supplementary Protection
Amperage
10
Number of Poles
1
Breaking Capacity
10 kA @ 277 VAC; 14 kA @ 240 VAC; 14 kA @ 120 VAC; 10 kA @ 65 VDC; 3 kA @ 415 VAC; 10 kA @ 240 VAC; 20 kA @ 60 VDC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
Clip
Voltage
277 V
Wire Size (AWG)
18-8
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Height (Decimal Inch)
3.1900
Overall Length (Decimal Inch)
2.8300
Overall Width (Decimal Inch)
0.7100
For Use With
OEM Panel
Standards Met
UL 1077; IEC; CSA; CCC
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 70 Amp, 600 VAC, 2 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14-3/0 AWG, 87.3mm Deep x 162.6mm High x 69.7mm Wide
Item #: 56748015
Brand: Square D
Model #: HGL26070
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
70
Number of Poles
2
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
600 VAC
Wire Size (AWG)
14-3/0
Maximum Operating Temperature (F)
104
Overall Depth (Decimal Inch)
3.4400
Overall Depth (mm)
87.30
Overall Height (mm)
162.60
Overall Height (Decimal Inch)
6.4000
Overall Width (mm)
69.70
Overall Width (Decimal Inch)
2.7400
For Use With
Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met
CSA Certified; IEC 647-2 Icu/Ics; NOM; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 1200 Amp, 480 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG
Item #: 56761786
Brand: Square D
Model #: PLL34120
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
1200
Number of Poles
3
Breaking Capacity
100 kA @ 480 VAC; 125 kA @ 240 VAC; 25 kA @ 600 VAC
Tripping Mechanism
Electronic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
480 VAC
Wire Size (AWG)
3/0
Standards Met
CSA; IEC; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 100 Amp, 250 VDC, 480 VAC, 3 Pole, Molded Case Circuit Breaker - Thermal Magnetic Trip, 18 kA at 240 VAC Breaking Capacity, 14-1/0 AWG, 3-3/8 Inch Deep x 6 Inch High x 4-1/8 Inch Wide
Item #: 04883112
Brand: Eaton Cutler-Hammer
Model #: EHD3100L
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
100
Number of Poles
3
Breaking Capacity
18 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Screw
Voltage
250 VDC; 480 VAC
Wire Size (AWG)
14-1/0
Overall Depth (Decimal Inch)
3.3800
Overall Depth (Inch)
3-3/8
Overall Height (Decimal Inch)
6
Overall Width (Inch)
4-1/8
Overall Width (Decimal Inch)
4.1300
Standards Met
CSA Listed; UL Listed 1053; UL Listed 489
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 125 Amp, 600Y/347 VAC, 3 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 100 kA at 240 VAC, 65 kA at 480 VAC, 25 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG
Item #: 41400672
Brand: Square D
Model #: BJL36125LU
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
125
Number of Poles
3
Breaking Capacity
100 kA @ 240 VAC; 65 kA @ 480 VAC; 25 kA @ 600Y/347 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
600Y/347 VAC
Wire Size (AWG)
14-3/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 100 Amp, 600Y/347 VAC, 3 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 VAC, 35 kA at 480 VAC, 18 kA at 600Y/347 VAC Breaking Capacity, 14-2/0 AWG
Item #: 41384421
Brand: Square D
Model #: BGA36100
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
100
Number of Poles
3
Breaking Capacity
65 kA @ 240 VAC; 35 kA @ 480 VAC; 18 kA @ 600Y/347 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
I-Line; Lug
Mounting Type
Panel Mount
Voltage
600Y/347 VAC
Wire Size (AWG)
14-2/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 45 Amp, 347 VAC, 1 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 277 VAC, 14 kA at 347 VAC Breaking Capacity, 14-3/0 AWG
Item #: 41399312
Brand: Square D
Model #: BDL16045
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
45
Number of Poles
1
Breaking Capacity
25 kA @ 240 VAC; 18 kA @ 277 VAC; 14 kA @ 347VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
347 VAC
Wire Size (AWG)
14-3/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It